Mini-Panel
CellsSaline RT
Screen Cell I 0
Screen Cell II 0
Screen Cell III 0
A1 cell 1+
A1 cell 1+
A1 cell 1+
A2 cell 0
A2 cell 0
A2 cell 0
autocontrol 0

RT: Room Temperature

Rationales for the tests:

  • Group O screen cells were tested to investigate the presence of unexpected cold-reactive antibodies such as anti-Lea, -M, -N, and -P1.
  • Three A1 and three A2 cells were tested to confirm anti-A1 with an acceptable probability (p) of 0.05 or less. This is achieved with three cells that are positive and three that are negative.
  • The autocontrol was set up to exclude autoanti-I.